Description
๐๐๐ฉ๐๐๐ข๐ญ๐ฒ (๐๐/๐๐๐ญ๐ญ๐ฌ) 1000VA/1000W
๐๐ก๐๐ฌ๐ ๐๐ข๐ง๐ ๐ฅ๐ phase with grounde with
๐๐๐๐๐
๐๐จ๐ซ๐ฆ๐ข๐ง๐๐ฅ ๐๐จ๐ฅ๐ญ๐๐ ๐ 200/208/220/230/240/Vac
๐๐ฉ๐๐ซ๐๐ญ๐ข๐ง๐ ๐ฏ๐จ๐ฅ๐ญ๐๐ ๐ ๐ซ๐๐ง๐ ๐
Low voltage of transferring to bypass
160Vacยฑ5%@100%~80% load 140Vacยฑ5%@80%~70% load 120Vacยฑ5%@70%~60% load 110Vacยฑ5%@60%~0% load (Ambient Temp. <35C)
Low threshold voltage of recovering from bypass
175Vacยฑ5%@100%~80% load 155Vacยฑ5%@80%~70% load 135Vacยฑ5%@70%~60% load 125Vacยฑ5%@60%~0% load (Ambient Temp. <35C)
๐๐ข๐ ๐ก ๐ฏ๐จ๐ฅ๐ญ๐๐ ๐ ๐จ๐ ๐ญ๐ซ๐๐ง๐ฌ๐๐๐ซ๐ซ๐ข๐ง๐ ๐ญ๐จ ๐๐ฒ๐ฉ๐๐ฌ๐ฌ 300Vacยฑ5%
๐๐ข๐ ๐ก ๐ญ๐ก๐ซ๐๐ฌ๐ก๐จ๐ฅ๐ ๐ฏ๐จ๐ฅ๐ญ๐๐ ๐ ๐จ๐ ๐ซ๐๐๐จ๐ฏ๐๐ซ๐ข๐ง๐ ๐๐ซ๐จ๐ฆ ๐๐ฒ๐ฉ๐๐ฌ๐ฌ 290Vacยฑ5%
๐๐ฉ๐๐ซ๐๐ญ๐ข๐ง๐ ๐ ๐ซ๐๐ช๐ฎ๐๐ง๐๐ฒ ๐๐๐ง๐ ๐ 40~70Hz
๐๐๐ง๐๐ซ๐๐ญ๐จ๐ซ ๐๐ง๐ฉ๐ฎ๐ญ Support
๐๐๐๐๐๐
๐๐ฎ๐ญ๐ฉ๐ฎ๐ญ ๐๐จ๐ฅ๐ญ๐๐ ๐ 200/208/220/230/240/Vac
๐๐จ๐ฐ๐๐ซ ๐ ๐๐๐ญ๐จ๐ซ 1.0
๐๐จ๐ฅ๐ญ๐๐ ๐ ๐๐๐ ๐ฎ๐ฅ๐๐ญ๐ข๐จ๐ง ยฑ1%
๐ ๐ซ๐๐ช๐ฎ๐๐ง๐๐ฒ
๐๐ข๐ง๐ ๐ฆ๐จ๐๐ (๐๐ฒ๐ง๐๐ก๐ซ๐จ๐ง๐ข๐ณ๐๐ ๐ซ๐๐ง๐ ๐) 47~53Hz or 57~63Hz
๐๐๐ญ. ๐ฆ๐จ๐๐ (50/60ยฑ0.1)Hz
๐๐ซ๐๐ฌ๐ญ 3:1
๐๐๐ซ๐ฆ๐จ๐ง๐ข๐ ๐๐ข๐ฌ๐ญ๐จ๐ซ๐ญ๐ข๐จ๐ง (๐๐๐๐ฏ) <2% THD (Linear load) / <4% THD (Non-Linear load)
๐๐๐ฏ๐๐๐จ๐ซ๐ฆ Pure Sineswave
๐๐ซ๐๐ง๐ฌ๐๐๐ซ ๐๐ข๐ฆ๐
๐๐ ๐ฆ๐จ๐๐ <-> ๐๐๐ญ๐ญ. ๐๐จ๐๐ Zero
๐๐ง๐ฏ๐๐ซ๐ญ๐๐ซ <-> ๐๐ฒ๐ฉ 4ms (Typical)
๐๐๐๐๐๐๐
๐๐๐ญ๐ญ๐๐ซ 12V9AH
๐๐ฎ๐ฆ๐๐๐ซ๐ฌ 2
๐๐๐๐ค๐ฎ๐ฉ ๐๐ข๐ฆ๐
Long run unit depends on the capacity of externel batteries
๐๐ฒ๐ฉ๐ข๐๐๐ฅ ๐๐๐๐ก๐๐ซ๐ ๐ข๐ง๐ ๐๐ข๐ฆ๐ (๐๐ญ๐๐ง๐๐๐ซ๐ ๐๐จ๐๐) 4 hours recover to 90% capacity
๐๐ก๐๐ซ๐ ๐ข๐ง๐ ๐๐จ๐ฅ๐ญ๐๐ ๐ 27.4VDCยฑ1%
๐๐ก๐๐ซ๐ ๐ข๐ง๐ ๐๐ฎ๐ซ๐ซ๐๐ง๐ญ (๐๐๐ฑ.) 1A or 2A
๐๐๐๐๐๐ ๐ ๐๐๐๐๐๐๐
๐๐ข๐ง๐ ๐๐จ๐๐ ๐๐๐ญ๐ญ๐๐ซ๐ฒ ๐๐จ๐๐
๐๐ฆ๐๐ข๐๐ง๐ญ ๐๐๐ฆ๐ฉ. <๐๐ ๐
105%~110%: UPS transfer to bypass after 10 minutes when the utility is normal
110%~130%: UPS transfer to bypass after 1 minute when the utility is normal
130%~150%: UPS transfer to bypass after 5 seconds when the utility is normal
>150%: UPS transfer to bypass immediately when the utility is normal
๐๐ ๐ <๐๐ฆ๐๐ข๐๐ง๐ญ ๐๐๐ฆ๐ฉ. <๐๐ ๐
105%~110%: UPS transfer to bypass after 10 minutes when the utility is normal
110%~130%: UPS transfer to bypass after 1 minute when the utility is normal
>130%: UPS transfer to bypass immediately when the utility is normal
๐๐ก๐จ๐ซ๐ญ ๐๐ข๐ซ๐๐ฎ๐ข๐ญ Hold whole system
๐๐ฏ๐๐ซ๐ก๐๐๐ญ ๐๐ข๐ง๐ ๐ฆ๐จ๐๐: Switch to bypass; Back up mode: Shut down UPS immediately
๐๐๐ญ๐ญ๐๐ซ๐ฒ ๐๐จ๐ฐ Alarm and switch off
๐๐๐ (๐๐ฉ๐ญ๐ข๐จ๐ง๐๐ฅ) Shut down UPS immediately
๐๐ฎ๐๐ข๐๐ฅ๐ & ๐๐ข๐ฌ๐ฎ๐๐ฅ ๐๐ฅ๐๐ซ๐ฆ๐ฌ Line failure, Battery low, Overload, System fault
๐๐จ๐ฆ๐ฆ๐ฎ๐ง๐ข๐๐๐ญ๐ข๐จ๐ง ๐๐ง๐ญ๐๐ซ๐๐๐๐ USB, RS232, SNMP card (optional), Relay card (optional)
๐๐๐ซ๐ซ๐๐ง๐ญ๐ฒ 1 Years manufactory warranty.